Central Coast - 8x Storey Commercial High Rise Development
Jul 21,2016
106x Screw Piles installed at 6m-9m depth
Location:
Pine Tree Drive, Terrigal
Geotechnical Engineer:
JK Geotechnics
Structural Engineer:
United Engineers
Value:
$115,000
Duration:
6 days
Project Description
Originally Designed for concrete bored piles. Piling Experts Studied and examined the geotechnical conditions of the ground and proposed an alternate Screw Pile design which could accommodate the loads required. The Time, costings and traffic around the site were almost halved with the approved screw pile proposal by Piling Experts. Total of 106 Screw Piles installed to 6m depth, with 2x Static Load Tests performed by our team.